ultracam observing log      New Technology Telescope
file object date  utc start   utc end    num     flag     mode     exp     cycle     filter   nblue   size1     x1l, x1r     y1s     size2     x2l, x2r     y2s     size3     x3l, x3r     y3s     bin     gain   vclock  temps  slide  id pi observers  revision   file   comments
run016   BD Pav   13/04/2018   07:31:49 10:28:36 3676 data 2-WIN 11.5 2886.1 u' g' i' 3 512 x 510 1, 513 1 1 x 1 CDD 8C0000 -40,-40,-40 515 0101.C-0273 Gaensicke trm, afp 100222   run016   Science, reduced exposure time. Eclipse-like feature at 09.55 UT. Ran into twilight.
run015   BD Pav   13/04/2018   07:21:57 07:31:41 118 data 2-WIN 2131.5 4991.8 u' g' i' 3 512 x 510 1, 513 1 1 x 1 CDD 8C0000 -40,-40,-40 515 0101.C-0273 Gaensicke trm, afp 100222   run015   Science, focus at the beginning.
run014   BD Pav   13/04/2018   07:13:04 07:19:37 131 data caution 2-WIN 151.5 3025.0 u' g' i' 1 512 x 510 1, 513 1 1 x 1 CDD 8C0000 -40,-40,-40 1100 0101.C-0273 Gaensicke trm, afp 100222   run014   Acquisition.
run013   WD 1145+017   12/04/2018   23:42:40 07:07:04 2656 data 4-WIN 8550.5 10042.7 u' g' i' 2 251 x 200 181, 513 1 250 x 304 263, 513 721 1 x 1 CDD 8C0000 -40,-40,-40 1100 0101.C-0273 Gaensicke trm, afp 100222   run013   Science, proper run. Near bad column in g. Moved left at frame 170. Seeing 2". Started in a 30 minute long 0.1 mag dip. Fiddled with focus at start. Few thin clouds passing. Good data. Bumped a bit more left at frame 830. Nice dip 150 mins in. Clouds build up after 6 hours.
run012   WD 1145+017   12/04/2018   23:37:47 23:42:25 29 data caution 4-WIN 8550.5 9921.5 u' g' i' 2 251 x 200 181, 513 1 250 x 304 263, 513 721 1 x 1 CDD 8C0000 -40,-40,-40 1100 0101.C-0273 Gaensicke trm, afp 100222   run012   Science but mislabelled as acquistion. Usable.
run011   WD 1145+017   12/04/2018   23:26:33 23:37:30 130 data caution 4-WIN 2462.5 5089.8 u' g' i' 2 251 x 600 181, 513 1 250 x 304 263, 513 721 1 x 1 CDD 8C0000 -40,-40,-40 1100 0101.C-0273 Gaensicke trm, afp 100222   run011   Acquisition. Changed exposure time.
run010   WD 1145+017   12/04/2018   23:23:57 23:24:18 5 data caution 4-WIN 2462.5 5104.0 u' g' i' 2 251 x 600 181, 513 1 250 x 304 263, 513 721 1 x 1 CDD 8C0000 -40,-40,-40 -49 0101.C-0273 Gaensicke trm, afp 100222   run010   Acquisition. Changed position.
run009   Read out noise test   12/04/2018   20:25:31 20:25:43 5 technical FFCLR .5 2986.5 u' g' i' 1 1024 x 1024 1 x 1 FBB 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run009   Test to try to lower the read out noise.
run008   Read out noise test   12/04/2018   20:21:51 20:22:14 5 technical FFCLR .5 5807.7 u' g' i' 1 1024 x 1024 1 x 1 CDD 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run008   Test to try to lower the read out noise. Checked the cables at the telscope, everything is fine.
run007   Bias   12/04/2018   19:40:00 19:40:05 501 bias DRIFT .5 10.3 u' g' i' 1 60 x 60 362, 608 1 3 x 3 FBB 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run007   Bias for MAXI J1820+070 last night. NBLUE=1
run006   Bias   12/04/2018   19:33:09 19:33:15 501 bias DRIFT .5 10.3 u' g' i' 3 60 x 60 362, 608 1 3 x 3 FBB 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run006   Junk! Still had NBLUE=3 set. Bias for MAXI J1820+070 last night.
run005   Bias   12/04/2018   19:28:13 19:29:42 101 bias FFCLR .5 893.4 u' g' i' 1 1024 x 1024 2 x 2 FBB 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run005   Full-frame fast 2x2 bias.
run004   Bias   12/04/2018   19:24:30 19:27:10 101 bias FFCLR .5 1601.4 u' g' i' 1 1024 x 1024 2 x 2 CDD 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run004   Full-frame slow 2x2 bias.
run003   Bias   12/04/2018   19:18:34 19:23:33 101 bias FFCLR .5 2986.5 u' g' i' 1 1024 x 1024 1 x 1 FBB 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run003   Full-frame fast 1x1 bias.
run002   Bias   12/04/2018   19:06:58 19:16:38 101 bias FFCLR .5 5807.7 u' g' i' 1 1024 x 1024 1 x 1 CDD 8C0000 -40,-40,-40 -49 Calib Calib trm, afp 100222   run002   Full-frame slow 1x1 bias. All lights off in the dome. Nasymth shutter and focal plane slide in. Readout noise a little higher than yesterday but I noticed ESO had laid an extra line from EFOSC along our cables. Bias OK, no stray light noticeable.
run001       POWON   run001   Power on. Super u, g, i in place. Some cirrus, but OK.